Ambient RNA expression correction
1
0
Entering edit mode
10 months ago
Pac314 ▴ 10

Should ambient RNA expression correction (e.g. with SoupX) occur before or after initial QC for low-quality cells (e.g. filtering using RNA counts, mitochondrial fraction etc. when performing single-cell RNAseq analysis?

scRNAseq SoupX Seurat • 759 views
ADD COMMENT
0
Entering edit mode

Isn't ambient RNA filtered out by keeping only reads with cell barcodes that have a relatively high abundance?

ADD REPLY
0
Entering edit mode

Ambient RNA would have the same cell barcode as a valid cell-containing droplet since the RNA gets partitioned into the droplet with the cell.

ADD REPLY
2
Entering edit mode
9 months ago

Generally I correct for ambient RNA before the initial QC. It is the first step after getting the expression matrix from CellRanger for 10X assay. You would want to do the initial QC on cells that have been "decontaminated"

ADD COMMENT

Login before adding your answer.

Traffic: 1833 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6