Deciding if a study used Bulk or single-cell RNA sequencing using the GEO data
2
0
Entering edit mode
3 months ago
JACKY ▴ 140

I am reading several studies in GEO and having difficulty determining whether bulk RNA sequencing or single cell RNA sequencing was performed. I try to identify key clues like the type of normalization approach used or sequencing kits mentioned, but the distinction is not always clear to me (mainly I click on one of the samples and use what is written there). I would greatly appreciate any help in reviewing a few of these studies to assess if bulk or single cell RNA sequencing was used:

GSE125667, GSE99531, GSE118383, GSE98368, GSE125483

Thank you!

GEO RNA-seq • 853 views
ADD COMMENT
1
Entering edit mode
3 months ago
ATpoint 82k
  • GSE125667

Smart-seq is written in the methods text. That is single-cell. Every fastq file (pair) is a cell.

  • GSE99531

High molecular weight RNA (> 200 bp) was extracted from 2.000–40.000 cells

Bulk RNA-seq as they extracted from many cells.

  • GSE118383

Targeted RNA-seq libraries were built...

That's bulk as well, but targeted RNA-seq.

  • GSE98368

Bulk, no mention of single-cell.

  • GSE125483

As above.


Please see the method sections provided at GEO for submissions. They tell what the data are.

ADD COMMENT
0
Entering edit mode

So whenever I see Smart-seq, it's single-cell ? Also, I only need the relevant approach for the samples mentioned in the GEO page. So refering to the papers might be confusing sometimes, cuase they might mention stuff that are not relevant to the samples in GEO. For examples some papers may use both bulk and single-cell, but the provided samples in GEO would only be one of them.

ADD REPLY
0
Entering edit mode

Are you sure Smart Seq is single cell? I think it's fewer cells than bulk but not single cell and analysis wise is closer to bulk than sc.

ADD REPLY
0
Entering edit mode

I think Smart-seq in used in both bulk and single cell. So it's tuff here to identify which one is it ..

ADD REPLY
2
Entering edit mode

Read the methods. It's single-cell as suggested.

https://www.ncbi.nlm.nih.gov/geo/query/acc.cgi?acc=GSM3580020

Single cell cDNA libraries were using the SMARTSeq v2 protocol (Picelli et al., 2014) with the following modifications: 1. Use of 10 µM TSO; 2. Use of 250 pg cDNA with 1/5 reaction of Illumina Nextera XT kit (Illumina, San Diego, CA, USA). All samples were subjected to an indexed paired-end sequencing run of 2x51 cycles on an Illumina HiSeq 2000 system (Illumina, San Diego, CA, USA) (188 samples/lane).

ADD REPLY
0
Entering edit mode

Smart seq is single cell, but you are correct that analysis wise is closer to bulk (unlike 10X, it doesn't have UMIs; also unlike 10X; it's not only sequencing from the 3' end of reads; and also has greater depth per cell than 10X). Smart seq also uses plates rather than droplets (so all the droplet QCing sometimes done for 10X single-cell might not apply to smart-seq).

ADD REPLY
0
Entering edit mode

SMART-seq is a protocol for doing RNA-seq from very low amounts of input RNA. It is most commonly used for single-cell RNA-seq, but can also be used other sorts of low input sequencing (e.g. extra-cellular RNA, tissue slices etc).

ADD REPLY
1
Entering edit mode
3 months ago

Single Cell RNA-seq is relatively new, expensive, and difficult. If a study doesn't say that it is single-cell, I would assume that it is bulk.

ADD COMMENT
0
Entering edit mode

Agreed; look at both the GEO accession info and the methods of the paper. If it doesn't say single cell/nucleus, then it's bulk. When doing only "bulk" RNAseq in a study, people generally don't say "bulk RNAseq", they just say "RNAseq".

ADD REPLY

Login before adding your answer.

Traffic: 1629 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6