Illumina NextSeq SampleSheets
2
1
Entering edit mode
7.8 years ago
pablominguez ▴ 10

Hi all,

I have a illumina run with several projects inside (TruSeq Amplicon and Nextera Rapid Capture) and I cannot find how to configure the SampleSheet.csv to include for example the Assay type which are different or the adpaters. I just want to run bcl2fastq and at the moment I am creating separated SampleSheets and the run bcl2fastq with each one but really not sure if this will work. Does anyone know if I can just edit a single SampleSheet.csv and how :) .. or I have to work with several ones?

Thanks a lot!

next-gen ngs • 2.4k views
ADD COMMENT
0
Entering edit mode

Perfect, both solutions seems to work. Thanks a lot!

ADD REPLY
1
Entering edit mode
7.8 years ago
GenoMax 141k

If you are demultiplexing the data off-instrument there is no problem using multiple samplesheets and corresponding bcl2fastq v.2 runs.

ADD COMMENT
1
Entering edit mode
7.8 years ago

Assuming things like adapter type/length don't vary within a lane, then you can use the masking features of bcl2fastq rather than making multiple sample sheets.

ADD COMMENT

Login before adding your answer.

Traffic: 2517 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6